OPTIONS messaging
To stop the OPTIONS messaging spam, set "Qualify" to "no"
To keep OPTIONS messaging but slow down the rate, set "Qualify Frequency" to a value higher than 60.
NOTE: While it is possible to set a Line/Port # (SIP Username) that is different from the Authentication Username, PBX-in-a-Flash currently expects both to be the same value.
General Settings
Trunk Name: As appropriate
Outbound CallerID: Primary trunk DID
CID Options: Allow Any CID
Maximum Channels: As appropriate (should match Broadworks config)
Asterisk Trunk Dial Options:
Continue if Busy: Unchecked
Disable Trunk: Unchecked
Dialed Number Manipulation Rules
Assign an appropriate dial map
Outbound Dial Prefix: As appropriate
Outgoing Settings
Trunk Name: As appropriate
Peer Details:
disallow=allallow=alldtmfmode=rfc2833canreinvite=noinsecure=verycontext=from-trunkhost=FQDN/IPusername=Authentication Usernamesecret=Authentication Passwordtype=peerIncoming Settings
User Context: Authentication Username
User Details
secret=Authentication Passwordtype=usercontext=from-trunkRegistration
Register String:
SIP Username:Authentication Password@FQDN/IPNOTE: While it is possible to set a Line/Port # (SIP Username) that is different from the Authentication Username, PBX-in-a-Flash currently expects both to be the same value.